New High-Precision OSA Launched

Yokogawa's new AQ6380 OSA (Optical Spectrum Analyzer) offers extreme precision, with an optical wavelength resolution down to 5 picometers (pm) By DA Editor / 31 Aug 2021

Yokogawa has launched a new optical spectrum analyzer (OSA) designed to offer the extreme high precision demanded by researchers that are developing the next generation of optical communication components.

With the exponential growth of the IoT (Internet of Things), as well as cloud computing services, video broadcasting and conferencing, and the rise in access to mobile broadband, demand for data capacity will expand over the next few years. High capacity optical backhaul networks will be needed to serve this growing traffic density. 

DWDM (Dense Wavelength Division Multiplexing) is an optical multiplexing technology used to increase bandwidth over the existing fiber network. As data hungry applications push the performance requirements of DWDM systems, telecommunication channels become ever more closely spaced, making it more difficult to separate the individual channels in the WDM (Wavelength Division Multiplexing) analysis on an OSA. The AQ6380 offers excellent optical performance to allow engineers and scientists to develop and improve the speed, bandwidth and quality of the next generation of communication networks, while its ease of use ensures it can be operated quickly and efficiently.

“The AQ6380 is demonstrably the world’s best grating based OSA, outperforming its nearest competing solution on wavelength accuracy, resolution, dynamic range, and actual measurement speed,” says Terry Marrinan, Yokogawa Test & Measurement’s Vice President, Marketing, “The new product also offers a highly capable alternative to other measurement technologies, comparing favorably on wavelength range and actual dynamic range, and offering superior measurement speed and application adaptability, as well as a highly competitive price.”

A High-Accuracy Solution

As well as excellent optical wavelength resolution down to 5 picometers (pm), allowing optical signals in close proximity to be clearly separated and accurately measured, the AQ6380 allows waveforms that were previously not even visible in a typical OSA, such as modulation side peaks in the laser spectrum, to be accurately visualized. It also offers a wavelength range of 1200 to 1650 nm, allowing one unit to meet diverse wavelength measurement needs. With the ability to alter the wavelength resolution from 5 pm to 2 nm, a wide range of applications can be supported, from narrowband peak/notch measurements to wideband spectral measurements.

A major challenge for optical researchers has been maintaining the accuracy of their instruments, with ambient temperature change, vibrations, and shock all potentially affecting the measurement accuracy of optical spectrum analyzers. In response to this the AQ6380 features on board calibration based on a built-in light source, thus maintaining consistently high accuracy,. Wavelength calibration is automatically performed at set intervals by switching the optical path with an internal optical switch.

Improved Close-In Dynamic Range

Another important parameter in optical waveform analysis is close-in dynamic range, defined as the difference in power level measured from the peak of the signal to the noise at a specific distance from the peak wavelength. The AQ6380 features a newly designed monochromator with sharper spectral characteristics than previously available, achieving a close-in dynamic range of up to 65 dB. The result is that signals in close proximity can be clearly separated and accurately measured.

The new monochromator also offers very high stray light suppression, an important criterion in optical measurement.  For example, in situations such as laser SMSR (Side-Mode Suppression Ratio) measurement, where several optical spectra with different levels are measured at the same time, the stray light may interfere with the measurement. Here, the AQ6380 offers a light suppression value of 80 dB.

Fast measurement speed is another major benefit, with the AQ6380 capturing data points in only 0.23 seconds compared to 5.4 seconds for the existing model (AQ6370D) in certain conditions.

Further Features

  • High-resolution, responsive 10.4-inch touchscreen LCD 
  • Built-in analysis functions to characterize optical spectrum from a variety of optical systems and devices, such as WDM system, DFB-LD, EDFA, and filters
  • Analysis functions including: DFB-LD; FP-LD; LED; Spectral width (peak/notch); SMSR; Optical power; WDM (OSNR); EDFA (Gain and NF); Filter (peak/bottom) and WDM filter (peak/bottom).
  • “APP mode”: brings up an overview of the pre-installed testing apps – WDM, DFB-LD, FP-LD and LED testing. A guide through wizard leads the user through an easy set up process for specific measurements and analysis.

New or additional testing applications will be made available for download from the Yokogawa website and can be added to the AQ6380 by future firmware updates.

Posted by DA Editor Connect & Contact

Keep up to date with the latest news and
technical developments in Unmanned Systems.

Sign up to the UST weekly eBrief

By clicking "Sign me up" I consent to my personal information being processed for the purpose of sending me the 'eBrief' weekly e-newsletter. See our Website privacy policy.